No services found
No Products found
ProteoGenix
Elisa assay kits
96T
MATERIALS PROVIDED & STORAGE CONDITIONS
PART
Format
Description
STORAGE CONDITIONS
Pre-coated Microplate
1 plate
96 well polystyrene microplate (12 strips of 8 wells) precoated with recombinant human TIGIT antigen.
Store in sealed at -20℃.
Tiragolumab Standard
2 bottles
2000 ng/bottle of lyophilized Tiragolumab. Reconstitute in 1mL Standard Diluent before used.
Store at -20℃.
Detection A
1 vial
60 μL/vial of Biotin labeled Tiragolumab antibody (including preservative), 1:100 diluted by Assay Diluent before used.
Detection B
120 μL/vial of Streptavidin-HRP (including preservative), 1:100 diluted by Assay Diluent before used.
Standard Diluent
1 bottle
25 mL/bottle diluent (including preservative) was used to dilute the Standard and Samples .
Store at 4℃.
Assay Diluent
25 mL/bottle diluent (including preservative) was used to dilute the Detection A and Detection B.
20 × Wash Buffer
25 mL/bottle of a 20-fold concentrated solution of buffered surfactant with preservative, 1:20 diluted by deionized water before used.
Color Reagent
12 mL/ bottle of TMB (Tetramethylbenzidine) .
Stop Solution
6 mL/ bottle.
Plate Sealers
4 strips
Adhesive strips.
Store at RT.
* Provided this is within the expiration date of the kit.
OTHER SUPPLIES REQUIRED
• Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 630 nm or 620 nm.
• Pipettes and pipette tips.
• Deionized or distilled water.
• 500 mL graduated cylinder.
• Squirt bottle, manifold dispenser, or automated microplate washer.
• Test tubes for dilution of standards.
SAMPLE COLLECTION & STORAGE
The sample collection and storage conditions listed below are intended as general guidelines. Sample stability has not been evaluated.
Handle all blood and serum as if capable of transmitting infectious agents. The NCCLS provides recommendations for handling and storing serum and plasma specimens (Approved Standard-Procedures for the Handling and Processing of Blood Specimens, H18-A. 1990).
Serum - Use a serum separator tube (SST) and allow samples to clot for 30 minutes at room temperature before centrifugation for 15 minutes at 1000 x g. Remove serum and assay immediately or aliquot and store samples at ≤ -20℃. Avoid repeated freeze-thaw cycles.
Plasma - Collect plasma using EDTA, heparin, or citrate as an anticoagulant. Centrifuge for 15 minutes at 1000 x g within 30 minutes of collection. Assay immediately or aliquot and store samples at ≤ -20℃. Avoid repeated freeze-thaw cycles.
REAGENT PREPARATION
Bring all reagents to room temperature before use.
20-fold Wash Buffer Concentrate - If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have completely dissolved. Add 25 mL of Wash Buffer Concentrate to 475 mL of deionized or distilled water to prepare 500 mL of Wash Buffer.
Serum and Plasma - Serum and plasma samples require a 10-fold dilution. A suggested 10-fold dilution is 10 μL of sample + 90 μL of Standard Diluent (diluted 1:9). If the sample value is outside the range of the standard curve, the dilution can be adjusted appropriately and the assay can be redetermined. If the antibody concentration in the sample can be estimated and the assay can be performed simultaneously by diluting several gradients prior to the experiment.
Standard - Reconstitute with 1mL Standard Diluent, this reconstitution produces a stock solution of 2000 ng/mL. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. 2000 ng/mL is the first standard point, and the concentration of the 7 standard sample were 2000 ng/mL, 1000 ng/mL, 500 ng/mL, 250 ng/mL, 125 ng/mL, 62.5 ng/mL, 31.25 ng/mL respectively. The appropriate Standard Diluent serves as the zero standard (0 ng/mL).
Detection A (working solution) - Shake and mix before used. Centrifuge instantaneously with palm centrifuge to make the liquid at the bottom of the tube. Dilute the Detection A 1: 100 times to the working concentration with Assay Diluent.
Detection B (working solution) - Shake and mix before used. Centrifuge instantaneously with palm centrifuge to make the liquid at the bottom of the tube. Dilute the Detection B 1: 100 times to the working concentration with Assay Diluent.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is recommended that all standards and samples be assayed in duplicate.
1. Prepare all reagents and working standards as directed in the previous sections.
2. Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, and reseal.
3. Add 100 μL premixed solution (50 μL diluted standard/sample + 50 μL Detection A working solution) to each well . Cover with the adhesive strip provided. Incubate for 2 hours at 37℃.
4. Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (300 μL) using a squirt bottle, manifold dispenser, or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
5. Add 100 μL of Detection B (working solution) to each well. Cover with a new adhesive strip. Incubate for 30 minutes at 37℃.
6. Aspirate each well and wash, repeating the process five times. Wash by filling each well with Wash Buffer (300 μL) using a squirt bottle, manifold dispenser, or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
7. Add 100 μL of Color Reagent to each well. Incubate for 15 minutes at 37℃. Protect from light.
8. Add 50 μL of Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure
Reviews
There are no reviews yet.
Your email address will not be published. Required fields are marked *
Your review *
Name *
Email *
Save my name, email, and website in this browser for the next time I comment.
Related products
Got a question or need a quote? Message us and we’ll get back to you 48 hours or less.
First name
Last name
Email address
Lab / Company
Phone number
send
Your cart is currently empty.